Tecan’s experience in mass spectrometry and chromatography sample preparation spans from innovative instruments to consumables products to a deep understanding of required applications. Whether you need to extract THC and THC metabolites through liquid-liquid extraction (LLE), supported liquid extraction (SLE), or solid phase extraction (SPE), Tecan has the right automation solution for you.

The Resolvex® standalone instrument portfolio helps low- to mid-throughput laboratories easily with SLE and SPE. Compatible with many products of different vendors, Tecan also offers its own selection of SLE and SPE materials.
For full automation, Tecan`s flagship liquid handling platform Fluent® supports GLP-, GMP- or IVDR-validated workflows. With recent enhancements, including the Phase Separator for fully automated LLE, and the Resolvex i300 for SPE in 96-well and 1ml, 3ml, 6ml columns, Fluent is the ideal instrument for forensics applications involving drug analysis.
Tecan presents one of its most recent developments in the Resolvex® instrument series: the Resolvex® Prep, specifically designed for extraction workflows such as the extraction of tetrahydrocannabinolic acid (THCA) and terpenoids from cannabis flowers. This instrument provides a fully automated, end-to-end solution for sample preparation in chromatography and mass spectrometry, tailored for low- and medium-throughput laboratories.
The Resolvex Prep is built around the principles of simplicity in operation, heightened flexibility and unrivalled precision and accuracy, making it an essential tool for advancing laboratory workflows.

Simplicity in operation

The Resolvex Prep can be operational in less than an hour, thanks to its intuitive interface and automated calibration procedures. The smart software allows users to quickly create new workflows using a drag-and-drop function to select required hardware such as syringes, vials, and racks. Predefined coordinates further minimise setup time, enabling researchers to focus on their work with minimal delays.
Using a validated manual extraction and filtration procedure, the Resolvex Prep automates the following liquid handling steps, including extraction, filtration, and aliquoting into final vials, starting with 0.5 g of pre-weighed cannabis flowers in a 20 mL EPA enviro vial:

• Add 10 mL of ethanol (96%)
• Vortex for 10 minutes at 510 rpm
• Pause for 2 minutes to allow the cannabis flowers to settle
• Take 2 mL of supernatant and filter through a 0.2 µm syringe filter into intermediate vials
• Prepare final autosampler vials by aliquoting 900 µL of ethanol
• Add 100 µL of the supernatant filtrate to the prepared final autosampler vials

The entire autosampler rack is then seamlessly transferred for analysis.

Heightened flexibility

The Resolvex Prep features a modular deck layout that accommodates common laboratory sample and autosampler racks (Agilent®, Waters®, Shimadzu®, CTC®, EST®, Hitachi®), solvent reservoirs, and labware in interchangeable positions. Using radio-frequency identification (RFID), the instrument automatically identifies deck segments, while proximity sensors detect the presence or absence of labware.
The patented rotating foot provides operational advantages, enabling automated tool changes for analytical syringes, SPE cartridges, µSPEed syringes, syringe disc filters, controlled piercing of septa-sealed vials, as well as precise aspirating and dispensing. Its capabilities are further enhanced by features such as a wash station, an optional large volume dispenser, and an optional direct injection port.

Unrivalled precision and accuracy

The Resolvex Prep uses analytical syringes ranging from 10 µL to 10 mL to ensure exceptional reliability and accuracy in sample preparation. With 12 different syringes and tools available, users can tailor their workflows to meet specific requirements. The automated tool change system enables seamless transitions, empowering users with maximum flexibility.
The automated extraction process demonstrated excellent performance, yielding 25.4% total THCA at a 99.1% recovery rate and a 97.5% recovery rate for terpenoids, comparable to a GMP-validated manual protocol.
Capable of handling batch sizes from 5 to 50 samples with consistent efficiency and accuracy, the Resolvex Prep completes Tecan’s portfolio for sample preparation in mass spectrometry and chromatography for smaller laboratories.

Free to read

Articles are free to download. Please login to read this article or create an account.


Events

SETAC Europe

May 11 2025 Vienna, Austria

SIEE Pollutec

May 18 2025 Algiers, Algeria

23rd International Water Management Exhibition

May 20 2025 Prague, Czech Republic

IFAT Brasil

Jun 25 2025 Sao Paulo, Brasil

View all events

Great Job...
The latest issue will be with you shortly, why not tell your colleagues at your company about us?
Register for the latest products by eMail
- Register to the eBulletin, a Monthly email packed with the latest Pollution Solutions products, news and services. Its FREE